Re: Humidity and SL5170/5180
From:
Jim Harrison (Cutler Technologies)
Date:
Tuesday, October 11, 1994
From: Jim Harrison (Cutler Technologies)
To: Frost Prioleau (Plynetics Express Corporation)
Cc: RP-ML
Date: Tuesday, October 11, 1994
Subject: Re: Humidity and SL5170/5180
On Thu, 6 Oct 1994, Frost wrote:
> What effects are people seeing from humidity on solid SLA parts built with
> ACES or Wide-Weave building styles? Warpage? Surface tackiness? Dimensional
> instability?
The sensitivity of the resin that I have seen is scary! A part that was
built in march of 94 was placed in a bucket of water for 2 hours. The
results was a very flexible part. I could twist and bend it without
breaking it. This same part was built using aces build style and cured
for 30 minutes. Also, I have been told by others that this is how their
parts come out of the vat. I have only noticed the tackiness and once
the support structure was rubbery. I do know that 3D Systems has had to
swap out vats, (not sure how many), due to this problem. I have not
noticed any of the other mentioned problems.
Jim Harrison
Cutler Technologies
Previous message