RE: SLA350

From: DAN DAVIS, RAPID PROTOTYPE (DANIEL@pmisd.proton.com.my)
Date: Fri Jan 23 1998 - 06:42:34 EET


Jan,

You can use a text editor (VI, Jot, etc.) to modify the .cfg file that
Maestro uses to set up part builds. This file tells the NT buildstation
software the vat size. I think that the DOS buildstation software has
the vat size built in and ignores the instructions from Maestro.

Of course, one must be careful when modifying this file as it is very
easy to get into trouble by pushing the envelope too far!

Regards,
> Dan Davis
> Division Head, RP&M
> Perusahaan Otomobil Nasional Berhad (PROTON)
Hicom Industrial Estate
Batu 3 PO Box 7100
Shah Alam, Selangor D. E.
40918 MALAYSIA
> +60 3 515-3906 direct line
> +60 3 515-2380 direct fax
> +60 12 277-5770 hand phone
>
>
>
> ----------
> From: Andrzejewski, Jan[SMTP:jan_andrzejewski@peragroup.com]
> Sent: Friday, 23 January, 1998 12:04 AM
> To: rpml
> Subject: SLA350
>
>
> When is a SLA350 not a SLA350?
>
> Answer when you build using DOS rather than NT ( Build Station
> software
> version 4 )
>
> The software allows you to build in a volume of 350x350x400 in NT but
> the
> volume extents of building
> in DOS is 355.6 x 355.6 x 406.4



This archive was generated by hypermail 2.1.2 : Tue Jun 05 2001 - 22:44:45 EEST