RE: Buildstation 5.1 or Bitnerd Intuition

From: Blasch, Larry (LBlasch@OPW-FC.com)
Date: Wed Aug 30 2000 - 23:24:10 EEST


Just divide the tallest part's height by the layer thickness for builds that
don't auto-drain... are they evenly divisible by the blade sweep? (Are you
using more than one sweep per layer?) If not, move your tallest part up one
layer thickness. Don't forget to add that thickness to it's support height
or you might get a poor platform bond. That will get your blade to the front
of the vat at the end of the build. It still may not solve the problem
though...

Since I'm still using a dinosaur SLA 250, I don't need to worry about bugs
in the new buildstation software, I just didn't get any.

Larry

Lawrence R. Blasch
Design Engineer
CAE Systems Administrator
     
OPW Fueling Components
P.O. Box 405003
Cincinnati, OH 45240-5003 USA
Voice: (513) 870-3356
Fax: (513) 870-3338

*****************************************
* "Always remember you're unique,*
* just like everyone else." *
*****************************************

 

-----Original Message-----
From: Scott -Scooter- Sutterer [mailto:ssutter@pdmfg.com]
Sent: Wednesday, August 30, 2000 1:49 PM
To: RP-ML; jesalhus1@mmm.com
Subject: Re: Buildstation 5.1 or Bitnerd Intuition

Hello my name Scooter and I am a computer geek.

If this proves to be the problem, now you just have to figure out a work
around (or deal with it till 3D Systems fixes the problem). Maybe a really
small .stl combined with the tallest part to give the run the right height
to have an even number of sweeps.

Cheers

Scott "Scooter" Sutterer

----- Original Message -----
From: <jesalhus1@mmm.com>
To: <KDenton@williams-int.com>
Cc: <ssutter@pdmfg.com>; <rp-ml@bart.lpt.fi>
Sent: Wednesday, August 30, 2000 12:38 PM
Subject: RE: Buildstation 5.1

>
>
> I just watched my parts finish building in my SLA500. The blade was in the
front
> of the vat at the end of the build and the elevator rose to the drain
position.
> So I think Scooter might be correct about the blade being in the back when
the
> build is complete and the elevator won't drain after the blade moves to
the
> front.
> Regards,
> Jerry Salhus
>

For more information about the rp-ml, see http://ltk.hut.fi/rp-ml/

For more information about the rp-ml, see http://ltk.hut.fi/rp-ml/



This archive was generated by hypermail 2.1.2 : Tue Jun 05 2001 - 23:04:12 EEST