Sorry it took so long, but we have individual UPS back-ups on each machine here. The SLA250 machines have a Liebert UPStation GXT and the SLA5000 machines have a UPStation S. These provide a conditioned power supply to our machines so that no surges reach the machines. They also provide about 30-45 minutes of power when a total power loss is witnessed. You can contact Reece Clemens @ 614-841-2792. He should know exactly what we have here. They offer other systems too that can provide more back-up time. The last time I looked into it I could up-grade all my systems for ~ $12,000 so that I would have about 2-3 hours of back-up during a total power loss. We have yet to go that direction.
Paul Bordner
Laser Reproductions
501 Morrison Road, Suite 101
Gahanna, OH 43230
p 614.470.6905 f 614.470.6907
paulb@laserrepro.com www.laserrepro.com
----- Original Message -----
From: Rob Connelly
To: paulb@laserrepro.com
Sent: Wednesday, April 11, 2001 7:48 PM
Subject: Fw: battery backup for SLA250
Paul,
Could you tell me something about your setup?
Thanks in advance,
- Rob Connelly
----- Original Message -----
From: R. Eric "Dude" King
To: Vern Carter
Cc: Paul Bordner ; RP-mail list
Sent: Friday, April 06, 2001 7:29 PM
Subject: Re: battery backup for SLA250
Hey Vern,
Contact Paul Bordner at
Laser Reproductions - paulb@laserrepro.com
(614) 470-6905 voice
(614) 470-6907
They have an awesome set-up for their 250's & 5000's.
Best Regards,
Eric King
eric@solidimaging.com
www.solidimaging.com
Laser Innovations
SLA Service Dept.
668 Flinn Avenue
Suite #22
Moorpark, CA 93021-2074
805.529.5864 tel
805.529.6358 fax
Vern Carter wrote:
Anyone have a source for a UPS to power an SLA 250?Vern Carter
Creative Technical Solutions
6880 Hillsdale Court
Indianapolis, IN 46250
317-578-3445
fax 317-578-3446
www.3dresource.com
_________________________________________________
This e-mail and any attached file is intended only for the person or entity to which it is addressed and may contain information that is privileged, confidential or otherwise protected from disclosure. Dissemination, distribution or copying of this e-mail or the information herein by anyone other than the intended recipient, or an employee or agent responsible for delivering the message to the intended recipient, is prohibited. If you have received this email in error, please immediately notify us by calling the person listed above.
_________________________________________________
For more information about the rp-ml, see http://ltk.hut.fi/rp-ml/