Re: [rp-ml] Humidity control in Z-Corp. 3D Printer

From: <pgu_at_BIBUSDOEDIJNS.FR>
Date: Mon Feb 13 2006 - 12:31:04 EET

Dear Dr Adel,

In 3D Print Setup, you can adjust only the saturation level, the other
parameters are linked.

The anisotropic factor is for correcting the dimension changes in X, Y, Z
axis after post-treatment.

The quantity of binder going through the printhead jets is about 0,032 ml
per million pixel. It's an average quantity calculated with standart
saturation level.

For the clogged head : try to force jets with binder in the resevoir and a
seringe of air on the reservoir, or use an ultrasonic cleaner.

Best regards.

Philippe Guérin
_____________________________
Technico commercial Zcorp
Société BIBUS DOEDIJNS
Z.I. du Chapotin
69970 Chaponnay
Tél. : 04 78 96 80 00
Fax : 04 78 96 80 01
www.bibusdoedijns.fr